Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

...

...

...

Info

This article is valid for Smart ID 21.04 and later.


This article describes parameters in

...

the Physical Access database that are common for all PACS connectors. 

For more information, see Integrate Identity Manager with physical access control system (PACS)

Excerpt

group: messagingqueue

keyData typeRequired or OptionalDescription
serverstringRequired

IP Address of Message Queue Server. If it is installed on the local server then we can use localhost. If we are accessing this server remotely then need to mention IP address.

usernamestringRequired

Username of message queue server.

Default value: “guest”

passwordstringRequired

Password of message queue server.

Default value: “guest”

systemstringRequired

Defines which messaging queue to be used, either "rabbitmq" or "azureservicebus".

Default value: "rabbitmq"

group: general

keyData typeRequired or OptionalDescription
deleteUserOnNoEntitlementstringOptional

Defines if the user shall be deleted if no active entitlement assignment are present for that user.

Valid values: true or false.

Default: true

deleteUserOnNoAccessTokenstringOptional

Defines if the user shall be deleted if no active access tokens are present for that user.

Valid values: true or false.

Default: true 

heartbeatInterval

intOptional

Heartbeat interval is the time difference between two successive heartbeats, and it is used to know if the system is in active (running) or in inactive (stopped) state.

Default value and minimum value: 60 seconds. If it is set less than 60 seconds, it will be considered as 60 seconds to update the status

...

.


Related information