Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Minor
Info

This article is valid for Smart ID 20.11 and later.

...

Expand
titlePrerequisites

The following prerequisites apply:

  • Servers must have the following installations:
  • Clients must have the following installations:

Step-by-step instruction

Expand
titleIntegrate Identity Manager with Smart ID Messaging
  1. Set up communication between Identity Manager and Smart ID Messaging over HTTPS. See Integrate Identity Manager with Smart ID Messaging.  

Troubleshooting

Note

Popups must be allowed for the running Identity Manager server to be able to call the Smart ID Desktop App plugout URL. Most browsers block them by default and show a very subtle hint that a popup was blocked.

If the Smart ID Desktop App plugout URL is not called, check your browser's URL bar for any indication about blocked popups and add an exception.

...

Expand
titleTroubleshooting

To troubleshoot Smart ID Desktop App, consult the logfile. Here are some common errors and suggestions how to fix them:

Virtual smart card creation failed - Insufficient resources

Error: Virtual Smart Card creation failed! --> System.Exception: The target device has insufficient resources to complete the operation. (Exception from HRESULT: 0x80070142)

Solution: Remove some virtual smart cards and try again.

Virtual smart card creation failed - Operation requires elevation

Error: Virtual Smart Card creation failed! --> System.Exception: The requested operation requires elevation. (Exception from HRESULT: 0x800702E4)

Solution: Make sure you follow the prerequisites listed above. Login as administrator and try again.

Domain mismatch

Error: Domain mismatch error message

Solution: Make sure you use HTTPS for Identity Manager and Hermod

Smart ID Desktop App crashes

Error: Smart ID Desktop App crashes

Solution: Update Windows

...


Additional information

Expand
titleUseful links

...

...