Version: 1.8.3
Release date: 2022-04-05
Version 1.8.3 of Smart ID Desktop App replaces these versions, and all included features and corrected bugs from these versions are included in 1.8.3, see a list below:
- Smart ID Desktop App 1.7.3
- Smart ID Desktop App 1.7.5
- Smart ID Desktop App 1.8
- Smart ID Desktop App 1.8.1
- Smart ID Desktop App 1.8.2
Detailed features list
Features
Jira ticket no | Description | From version |
---|---|---|
PEX-1004 | The transport public key format has been changed from plain public key to JWK. PS256 remains. | 1.8.1 |
PEX-1012 | Localization for French has been added. | 1.8.1 |
PEX-1016 | Added an option to delete any corresponding certificates when a temporary card is removed. | 1.8.1 |
PEX-844 | Added support for P12 import from file into Virtual Smart Card (VSC) profile without the need for pre-creation of the VSC. Read more here: Create virtual smart card | 1.8 |
PEX-946 | Added support for PIN reset / Adminkey change for Smart Cards not related to any profile in Smart ID Desktop App. | 1.8 |
PEX-969 | Windows 10 revision 1903 or higher is required for MS Store version of Smart ID Desktop App. See here: Smart ID Desktop App requirements and interoperability. | 1.8 |
PEX-991 | Upgrade from sideload to MSI version and vice versa is now supported. | 1.8 |
PEX-938 | Limited support for provisioning physical smartcards. General minidriver cards are supported. Specifically tested and supported with CardOS minidriver, Gemalto/Axalto minidriver and Crescendo C2300. | 1.7.5 |
PEX-947 | Added a switch in advanced settings for automatic removal of encryption certificates, used for protecting P12 certificates during enrollment and installation. See Advanced settings in Smart ID Desktop App. | 1.7.5 |
Corrected bugs
Jira ticket no | Description | From version |
---|---|---|
PEX-1038 | Fixed a certificate filtering error that prevented signing to work when certain class of certificates were present. | 1.8.3 |
PEX-1041 | Single profile desktop extension extended to Software and Platform profiles. | 1.8.3 |
PEX-1043 | Added "sideloaded" in the version of the Sideloaded release in About to distinguish it from the Store release. | 1.8.3 |
PEX-1044 | Logs were erroneously truncated, which has been fixed. Date format changed to yyyy-MM-dd. | 1.8.3 |
PEX-1003 | Newly provisioned virtual smartcard (VSC) was supposed to have an administrative key set to the value received from the server. Instead, a default value was used. As a consequence, VSC with provisioned email decryption or authentication key could be used without the knowledge of the PIN. This has been fixed. | 1.8.2 |
PEX-1036 | Date in format dd-mm-RR was added to the Smart ID Desktop App logs. | 1.8.2 |
PEX-1028 | Profileless adminkey change is now possible by listing smartcardid. This is a part of wider support for minidriver based physical smartcard. | 1.8.2 |
PEX-1026 | Metadata tool stopped signing data with the latest library update. This has been fixed. | 1.8.2 |
PEX-1025 | Messaging which occurs when provisioning goes wrong was updated to be more transparent. | 1.8.2 |
PEX-977 | Sonarqube failed when building Smart ID Desktop App. This has been fixed. | 1.8.1 |
PEX-1007 | Virtual Smartcard pin reset was not working, it complained about missing token. This has been fixed. | 1.8.1 |
PEX-1009 | Sonarqube sometimes fails due to connectivity errors when building Smart ID Desktop App. This has been fixed. | 1.8.1 |
PEX-1018 | Some localization strings where untranslated. This has been fixed now. | 1.8.1 |
PEX-1019 | Some scripts behaved differently on domain machines. This has been fixed now. | 1.8.1 |
PEX-1025 | If a Provision command fails, then Desktop App should roll back to its previous state. This is working as it should now. | 1.8.1 |
PEX-1026 | Metadata signing feature stopped working with the new azure library update. This has been fixed now. | 1.8.1 |
PEX-891 | Solved an issue where the complete Yubikey could be deleted instead of the intended Yubikey profile. | 1.8 |
PEX-984 | Solved an issue where PIN reset for a VSC did not work. | 1.8 |
PEX-985 | Solved an issue where the replace VSC process failed with "AdminKeyChangeFailed" error. | 1.8 |
PEX-995 | Solved an issue with JWT cross-platform inconsistency manifested in the Smart ID Desktop App. | 1.8 |
PEX-934 | There was an issue with a pre-activation provisioning attribute. This has been fixed. | 1.7.5 |
PEX-949 | Removed a non-used activation link button from the UI. | 1.7.5 |
PEX-951 | Logging has been unified and enhanced. Native and framework processes now log to common file, which simplifies Pencode scripts debugging. | 1.7.5 |